Case   
Contact Us   
Search   
Your Position: Home > Case > Case2

Design of American Metal Buildings

2024-5-25 9:11:56

No Pics.

Introduction
Design of American Metal Buildings

ZHM Huawu Steel has designed and manufactured 17 units of steel structure warehouse buildings in Hawaii, USA, all of which are in accordance with the design standards of American Metal Buildings. We have provided a comprehensive set of design drawings, calculation reports, and installation drawings for each unit.

Metal_Building_Warehouse_in_America_1_Malakole-Warehouse-1024x576

Steel Warehouse in Hawaii

Steel Warehouse Buildings in America


Table of Contents


1.General of Design of American Metal Buildings
1.1.Design Loads
2.Building Code for Design of American Metal Buildings

2.1.Welding


General of Design of American Metal Buildings


1.The design is for Malakole Warehouses, Kapolei, Oahu, Hawaii
2.Discrepancies. Metal Building Supplier shall verify all dimensions and conditions and shall report any discrepancies in writing to the owner before commencing work or ordering materials.
3.All materials and quality shall conform to the requirements of the local building code in addition to the Codes cited.
4.Details shown on the drawings shall be typical for all similar conditions.
5.Modify details for particular requirements as directed by the owner.
6.Metal Building Supplier to include in its bid or proposal, any costs to change the structural supports to accommodate actual equipment or item used.
7.Roof Slope 1:12
Design_of_American_Metal_Buildings_1_Design-of-American-Metal-Buildings

Steel Warehouse in Hawaii

8.Metal Structure Buildings


Design Loads

(1)Live Load: Roof 20psf(Reducible Per IBC 1607.9)


The reduction cannot exceed 50 percent for elements that support loads of a single floor.

20 psf of roof live load may not reduce to less than 12 psf


(2)Additional Superimposed Dead Load


Roofing 2psf
Mechanical/Electrical/Ceiling Hung System 5psf

Collateral Loads 5psf


(3)Lateral Load


Wind Load: Design Wind Speed 105mph, Exposure B, Enclosed Building, Importance Factor
I=1.0, Internal pressure coefficient= /- 0.18
Seismic Load: Ss=0.546g, S1=0.152g, Sds=0.496g, Sd1=0.222g, Importance Factor=1.0, Site
Classification: C, Seismic Design Category: C, Cs=0.15, R=3.25, Seismic force-resisting system:
Ordinary steel concentric braced frame

Design_of_American_Metal_Buildings_2_Design-of-American-Metal-Buildings1

Steel Warehouse in Hawaii

Metal Building Design


Building Code for Design of American Metal Buildings

Load Code for the Design of Building Structures (GB50009-2001)
Code for Seismic Design of Building (GB50011-2010)
Code for Design of Steel Structures (GB 50017-2003)
Technical Specification for Steel Structure of Light Building with Gabled Frames (CECS 102-2002)

Design_of_American_Metal_Buildings_3_Design-of-American-Metal-Buildings2

Steel Warehouse in Hawaii

Design of American Metal Buildings


Pre-engineered metal building and building cladding system for the above-referenced job per the plan and specification as follows:


Main Structure
Steel Column/Steel Beam: GB/T1591 – Q345B
Secondary Structure
Bracing/Purlin/Tie Beam/Steel Rod: GB/T700 – Q235B
Wall and Roof Panel
GB50003-2011
Trim/Gutter/Flashing
GB50003-2011

Design_of_American_Metal_Buildings_4_Design-of-American-Metal-Buildings-2-768x385

Steel Warehouse in Hawaii

Prefab Steel Buildings 
Design_of_American_Metal_Buildings_4_Design-of-American-Metal-Buildings-2-768x385

Steel Warehouse in Hawaii

American Prefab Metal Buildings 

Roof Panel: Corrugated Steel Sheet YX25-205-820, 24Ga
Wall Panel: Corrugated Steel Sheet YX25-205-900, 24Ga
Translucent Panel: PVC Sheet YX25-205-900, 0.04” thick.
Trim, Gutter, and Flashing: Galvanized 0.02” thick.
Down Pipe: PVC

Welding


1.All welding shall follow the provisions of the American Welding Society Code AWS-D101, latest edition.
2.All welding shall be done by certified welders holding current and valid AWS certificates and having current experience in the type of weld called for.
3.All welding shall be done by the shielded arc process using approved electrodes per AWS specifications E70xx (low hydrogen electrodes).
4.All welds shall have a weld-controlled sequence and technique to minimize shrinkage stresses and distortion.
5.All electrode filler materials shall be a minimum of E70xx.
6.Welding of sheet metal shall be following the 2006 IBS section 2204.1
7.Identify special procedures for field welding of structural steel elements which have been hot-dip galvanized after fabrication. Procedures shall ensure the weld’s quality by removing zinc materials during welding procedures.

8.All welding done after galvanization shall be protected with two coats of “galvalloy” or approved equal.


Why ZHM Huawu Steel Prefabricated Warehouse Building?



Reliable_and_customized_DesignsG
Cutting_edge_designing_process
Free_online_Pricing_System
Easy_Bolt-by-number_Assembly
Reliable and Customized Designs Cutting Edge Designing Process Free Online Price System Easy Bolt-by-number Assembly
Over_two_decades_of_Experiencey
Value_Engineering_for_Money
Unmatched_In_Quality
Excellent_Customer_Service
Over Two Decades of Experience Value For Money Unmatched in Quality and Craftmanship Excellent Customer Service



Would you like to see more information and images of ZHM’s Metal Steel Structure Warehouse Building ? Visit our Photo Gallery.

HOW CAN WE HELP YOU?

ZHM’s world-class team — together with our raw material suppliers and subcontractors — works to solve your most challenging design, engineering, farbrication or construction issues.

Contact ZHM by telephone at +86 135-8815-1981 or send us your questions via email to info@zhmsteelworks.com

More Pics