STG Steam Tubine and Generator House for Waste Heat Recovery Power Plant,Ghana | Made In China ZHM


Corrently, our one client in Ghana are planning to expand their current Gas Turbine Power Plants with the expansion of 1x22MW and 2x22MW Waste Heat Recovery Power Plant(WHR), Wassa/Chirano/Edikan, Ghana to upgrade the energy efficiency of all the current gas turbine power plants for more economic purpose, and we were honorably contracted for this expansion project of offer the STG Steam Tubine and Generator House for 1x22MW Waste Heat Recovery Power Plant,Ghana.


The followings are the main drawings and parameters of the WHR power plant and the STG Steam Tubine and Generator Houses


STG_Steam_Tubine_House_Generator_Building_Waste_Heat_Recovery_Power_Plant_Ghana_01a_3D-Perspective1

3D perspective view of the STG Steam Tubine and Generator House for Waste Heat Recovery Power Plant,Ghana 

-3 Sets 1x22MW and 1 set 1x22MW

STG_Steam_Tubine_House_Generator_Building_Waste_Heat_Recovery_Power_Plant_Ghana_01b_3D-Perspective

3D perspective view of the STG Steam Tubine and Generator House for Waste Heat Recovery Power Plant,Ghana 

-3 Sets 1x22MW and 1 set 1x22MW

STG_Steam_Tubine_House_Generator_Building_Waste_Heat_Recovery_Power_Plant_Ghana_01c_3D-Perspective

3D perspective view of the STG Steam Tubine and Generator House for Waste Heat Recovery Power Plant,Ghana 

-3 Sets 1x22MW and 1 set 1x22MW

STG_Steam_Tubine_House_Generator_Building_Waste_Heat_Recovery_Power_Plant_Ghana_01_1x22MW_Thermodynamic_System-Diagram

1x22MW Thermodynamic System Giagram Layout  of the STG Steam Tubine and Generator House for Waste Heat Recovery Power Plant,Ghana 

 

STG_Steam_Tubine_House_Generator_Building_Waste_Heat_Recovery_Power_Plant_Ghana_02_1x22MW_Steam_turbine_House_Section_Vi

1x22MW Section View  of the STG Steam Tubine and Generator House for Waste Heat Recovery Power Plant,Ghana 

STG_Steam_Tubine_House_Generator_Building_Waste_Heat_Recovery_Power_Plant_Ghana_03_1x22MW_Steam_turbine_House_Section_Vi


STG_Steam_Tubine_House_Generator_Building_Waste_Heat_Recovery_Power_Plant_Ghana_04_2x22MW_Thermodynamic_System-Diagram

2x22MW Thermodynamic System Giagram Layout  of the STG Steam Tubine and Generator House for Waste Heat Recovery Power Plant,Ghana 

STG_Steam_Tubine_House_Generator_Building_Waste_Heat_Recovery_Power_Plant_Ghana_05_2x22MW_Section_View

2x22MW Section View of the STG Steam Tubine and Generator House for Waste Heat Recovery Power Plant,Ghana 

STG_Steam_Tubine_House_Generator_Building_Waste_Heat_Recovery_Power_Plant_Ghana_06_2x22MW_Section_View


STG_Steam_Tubine_House_Generator_Building_Waste_Heat_Recovery_Power_Plant_Ghana_07_2x22MW_Structure_Section

Structure Section  of the STG Steam Tubine and Generator House for Waste Heat Recovery Power Plant,Ghana 


36/10ton Overhead Crane for installation and future repair and maintenance of the STG Steam Turbine and Generator:


工程代号及名称
PROJECT
1x22MW WHR PROJECT FOR THE PLANT IN GHANA     
APPROVED
项目代号及名称
DEPARTMENT
012-TURBINE AND GENERATOR DEPARTMENT
012-汽轮发电机房
   
CHECKED
文件编号
DOCUMENT No.
012-H-SBB    
DESIGNED
Slow-speed bridge crane
慢速桥式起重机
Set
4
Model
型号
Span(LK)
跨距
m 13.5
Capacity of main hook
主钩起重量
t 36
Capacity of vice hook
副钩起重量
t 10
Working grade
工作级别
A3
Lifting height of main hook
主钩起升高度
m 10
Lifting height of vice hook
副钩起升高度
m 12
Lifting speed of main hook
主钩起升速度
m/min 1.97
Lifting speed of vice hook
副钩起升速度
m/min 9.28
Moving speed of crane
大车运行速度
m/min 26
Moving speed of trolley
小车运行速度
m/min 17
Max. wheel pressure
最大轮压
kN
Track
轨道
Power of all motors
功率
kW 28
Voltage rating
电压
V AC 415


Why ZHM Huawu Steel Metal STG Steam Tubine and Generator House for Waste Heat Recovery Power Plant?


Reliable_and_customized_DesignsG
Cutting_edge_designing_process
Free_online_Pricing_System
Easy_Bolt-by-number_Assembly
Reliable and Customized Designs Cutting Edge Designing Process Free Online Price System Easy Bolt-by-number Assembly
Over_two_decades_of_Experiencey
Value_Engineering_for_Money
Unmatched_In_Quality
Excellent_Customer_Service
Over Two Decades of Experience Value For Money Unmatched in Quality and Craftmanship Excellent Customer Service

Would you like to see more information and images of ZHM’s Metal Steel Structure STG Steam Tubine and Generator House for Waste Heat Recovery Power Plant ? Visit our Photo Gallery.

HOW CAN WE HELP YOU?

ZHM’s world-class team — together with our raw material suppliers and subcontractors — works to solve your most challenging design, engineering, farbrication or construction issues.

Contact ZHM by telephone at +86 135-8815-1981 (wechat and whatsapp) or send us your questions via email to info@zhmsteelworks.com

More Pics